An Audit of Shade Reproduction of Fixed Metal Ceramic Prostheses

DOI: 10.1922/EJPRD_966Finch05

Abstract - This investigation aimed to evaluate the colour difference between metal ceramic restorations and their corresponding shades and any reasons for a colour mismatch in the dental laboratory. The colour of 50 consecutive metal ceramic restorations produced in a laboratory was measured using a spectrophotometer and compared to the shade tabs. Colour reproduction was optimal at porcelain thicknesses between 1.4-1.6mm, varied between technicians within the same laboratory and was better for shades in the 2M group. Most crowns were above the threshold for a clinically acceptable shade match and almost all crowns were lighter than the corresponding shade tab.

KEY WORDS: Shade reproduction, Spectrophotometry, Metal ceramic restoration