SCImago Journal & Country Rank
Clarivate Analytics
PubMed
Embase


European Journal of Prosthodontics and Restorative Dentistry  —  Vol. 23, Issue 4 (December 2015) ← Back to issue

The Effect of Disinfection Techniques on the Flexural Strength of Thermopolymerisable Acrylic Resins With or Without Pigment Addition

DOI: 10.1922/EJPRD_1343Goiato06

The Effect of Disinfection Techniques on the Flexural Strength of Thermopolymerisable Acrylic Resins With or Without Pigment Addition

Marcelo Coelho Goiato, Bruna Carolina Rossatti Zuccolotti, Marcela Filié Haddad, Amália Moreno, Aldiéris Alves Pesqueira, Humberto Gennari Filho, Daniela Micheline dos Santos

ABSTRACT

Objectives: The aim of this study was to assess the flexural strength of two brands of thermopolymerisable acrylic resins (Onda Cryl, Artigos Odontológicos Clássico Ltda, São Paulo, SP, Brazil; and Lucitone 550, Dentsply, York, PA, USA) with varying concentrations of pigment (Poli-Côr, Artigos Odontológicos Clássico Ltda, São Paulo,SP, Brazil) under the influence of thermocycling, storage and disinfection. Material and Methods: A total of 210 samples were manufactured (105 for each acrylic resin brand), with dimensions of 64 x 10 x 3.3 mm. The samples were divided into 30 subgroups (n=7) according to the proportion of pigment used (without pigment, 3% and 7%), the assessment period (initial or thermocycling for 2000 cycles) and disinfection method (immersion in 1% sodium hypochlorite, (Apothicário, Araçatuba, SP, Brazil), microwave energy or immersion in alkaline peroxide (Efferdent, Pfizer, Morris Plains, NJ, USA). The samples were submitted to the flexural strength test before and after thermocycling, and after storage with disinfection. The disinfection process was performed every 3 days, for 60 days. Data were submitted to analysis of variance (ANOVA) and Tukey test (p<0.05). Results: The factors that provided statistical alteration in flexural strength values were resin type and assessment period. The Onda Cryl resin and the period after disinfection (126 ± 25 MPa) exhibited the higher values of flexural strength. Conclusion: Following disinfection, Onda-Cryl resin exhibited the highest values of flexural strength. All the samples obtained are considered clinically acceptable.

Keywords

Acrylic Resins Color Stability Flexural Strength

Article Information
Pages
193 – 198
Cover Date
December 2015
Volume
23
Issue
4
Print ISSN
0965-7452
Electronic ISSN
2396-8893
no access

You do not currently have access to this article.

£10.00

Or subscribe to the journal for full access to all articles.