SCImago Journal & Country Rank
Clarivate Analytics
PubMed
Embase


European Journal of Prosthodontics and Restorative Dentistry  —  Vol. 24, Issue 2 (June 2016) ← Back to issue

The British Society of Prosthodontics 2016 Conference: Manchester

ABSTRACT

Clinical efficiency of one-piece screw-type implants with telescopic were attachments evaluated in this study. Twenty-four patients received a mandibular implant-supported overdenture and maxillary complete denture. Ninety-six one-piece implants were inserted in the inter-foraminal area. Implants were immediately loaded with an implant-retained overdenture and telescopic attachments which had frictional retention elements. There was 0.25±0.24 mm, 0.32±0.25 mm, 0.43±0.30 mm, 0.61±0.30 mm and of bone resorption after 3, 6, 12 and 24 months, respectively. The need to activate the frictional retention was the most common complication. Treatment outcomes for prefabricated telescopic retained overdentures on one-piece implants are similar to that obtained in cases of delayed loading.

Keywords

Osseointegration Telescopic Overdenture One-Piece Implant

Article Information
Pages
86 – 88
Cover Date
June 2016
Volume
24
Issue
2
Print ISSN
0965-7452
Electronic ISSN
2396-8893
no access

You do not currently have access to this article.

£10.00

Or subscribe to the journal for full access to all articles.