Acrylic Reinforcement with Off the Shelf Perforated Metal Plates

DOI: 10.1922/EJPRD_01575Abdulhameed05
ABSTRACT

To evaluate the effect of Dentaurum Grid Strengthener on flexural strength and modulus of two types of PMMA, 24 beams(75 mm x 10 mm x 2.5 mm) containing bonded and flattened Grid Strengthener and 24 beams without Grid Strengthener were subjected to a 3-point bending test at 5 mm/min. Flexural strength and modulus were calculated. Data were analyzed with a 2-way ANOVA. The highest mean strength and flexural modulus was measured for reinforced high impact resin (96.2±14.3 MPa and 3425±779 MPa, respectively). For flexural strength and modulus, resin and reinforcement had a significant effect. Clinical Relevance: Independent of the resin used, the incorporation of a grid strengthener increases the strength and modulus, thus the fracture probability of dentures is reduced.

Keywords

PMMA Reinforcement High Impact Metal Plate

Article Information
Pages
192 – 196
Cover Date
December 2016
Volume
24
Issue
4
Print ISSN
0965-7452
Electronic ISSN
2396-8893
no access

You do not currently have access to this article.