European Journal of Prosthodontics and Restorative Dentistry

10-Year Clinical Comparative Study of Ceramic and Composite Veneered Metal Crowns

Abstract

The rejection of composite veneerings in fixed partial dentures is primarily caused by the inadequacy of the bonds between the metal framework and the composite veneering. The development of improved veneering composites necessitates an investigation of their clinical suitability compared with ceramic materials. Nineteen patients with at least two suitable, adjacent natural teeth for crowning were treated with 64 high noble alloy crowns. The adjacent crowns were veneered with ceramic (IPS inline) and composite materials (SR Adoro). Seven follow-up examinations were carried out over a period of 10 years. The crowns were investigated for mechanical defects, periodontal parameters, and discolorations. The survival rates of the ceramic veneered metal crowns
(CeMCs) and composite veneered metal crowns (CoMCs) at the 10-year follow-up were 87.1 and 87.9%, respectively. The success rates of the crowns after 10 years were 83.9% for CeMCs and 51.5% for CoMCs (log-rank test, p = 0.009). No significant differences between the groups were found in the periodontal parameters (Kruskal–Wallis one-way analysis of variance, ANOVA p > 0.05). After 10 years, discoloration patterns of the two materials differed significantly (Mann-Whitney-U-test, p = 0.017). Thus, despite the improvements associated with CoMCs, CeMCs remain the gold standard for veneered
metal crowns.Keywords
Mechanical Complications
Fixed Partial Dentures
Composite Veneerings
Ceramic Veneerings
Discolorations
Periodontal Parameter

Authors

Helene Bacher, Ramona Schweyen, Constanze Olms, Christin Arnold, Jürgen Setz, Jeremias Hey

Articles from this issue

Title / DOI Access Page Start Page End Purchase
Special Online Only Supplement: Abstracts from the 44th Annual Conference of the European Prosthodontic Association (EPA) 30th September - 2 October 2021 Athens, Greece free access 0 0 view
Accuracy, Reliability and Clinical Implications of Static Compared to Quantifiable Occlusal Indicators
10.1922/EJPRD_2202Qadeer12
no access 130 141 £10.00
A Comparative study on the Effectiveness of Augmented Reality on Denture Tooth Selection
10.1922/EJPRD_2132Ark09
no access 143 151 £10.00
Trueness and Precision Achieved With Conventional and Digital Implant Impressions: A Comparative Investigation of Stone Versus 3-D Printed Master Casts
10.1922/EJPRD_2114Mathey08
no access 152 159 £10.00
Micro-Computed Tomography Analysis of Fit of Ceramic Inlays Produced with Different CAD Software Programs
10.1922/EJPRD_2046Bayrak06
no access 160 165 £10.00
Microstructure and Surface Characteristics of Short Fiber Reinforced CAD/CAM Composite Blocks
10.1922/EJPRD_2207Mangoush09
no access 166 174 £10.00
Comparison of Fit Between Zirconia and Metal Copings Fabricated Conventionally or Using Different CAD/CAM Techniques
10.1922/EJPRD_2108Sambrook07
no access 175 181 £10.00
10-Year Clinical Comparative Study of Ceramic and Composite Veneered Metal Crowns
10.1922/EJPRD_2148Bacher11
no access 182 192 £10.00
  • free access Free Access