European Journal of Prosthodontics and Restorative Dentistry

Microstructure and Surface Characteristics of Short Fiber Reinforced CAD/CAM Composite Blocks

Abstract

Objective: The aim was to investigate certain surface properties and microstructure of an experimental short fiber-reinforced CAD/CAM composite block (SFRC) in comparison with different CAD/CAM, 3D-printing and manually-made commercial composites (Cerasmart 270, GC Temp PRINT, Pro3dure GR-17, Essentia U, Gradia Plus and everX Flow). Methods: A wear-test was performed using a chewing-simulator with 15000 cycles. Wear depth (n=6) was assessed by 3D optical-profilometer. Surface roughness (SR) before and after wearing-test was evaluated. A Vickers-indenter was utilized for evaluating surface microhardness (VH) and glossmeter was utilized to measure the surface gloss at 60°. The surface microstructure of each composite was investigated with SEM. Data
were statistically analyzed with analysis of variance ANOVA (p=0.05). Results: Significant differences in the surface properties were found according to the type of composite (p<0.05). Cerasmart 270 exhibited the highest VH (94.8 V) and lowest SR (0.18 Ra) values (p<0.05) among the composites tested. The lowest wear depth measurement was located for GC Temp PRINT (19.3 µm) which was not significantly different (p>0.05) from Cerasmart 270 (20.7 µm). Conclusion: Incorporation of fibers to the composite of the CAD/CAM block did not negatively influence the surface characteristics of composite.
Keywords
Wear
CAD/CAM
3D-Printing
Fiber Composite
Surface Gloss

Authors

Enas Mangoush, lippo lassila, Pekka K. Vallittu, Sufyan Garoushi

Articles from this issue

Title / DOI Access Page Start Page End Purchase
Special Online Only Supplement: Abstracts from the 44th Annual Conference of the European Prosthodontic Association (EPA) 30th September - 2 October 2021 Athens, Greece free access 0 0 view
Accuracy, Reliability and Clinical Implications of Static Compared to Quantifiable Occlusal Indicators
10.1922/EJPRD_2202Qadeer12
no access 130 141 £10.00
A Comparative study on the Effectiveness of Augmented Reality on Denture Tooth Selection
10.1922/EJPRD_2132Ark09
no access 143 151 £10.00
Trueness and Precision Achieved With Conventional and Digital Implant Impressions: A Comparative Investigation of Stone Versus 3-D Printed Master Casts
10.1922/EJPRD_2114Mathey08
no access 152 159 £10.00
Micro-Computed Tomography Analysis of Fit of Ceramic Inlays Produced with Different CAD Software Programs
10.1922/EJPRD_2046Bayrak06
no access 160 165 £10.00
Microstructure and Surface Characteristics of Short Fiber Reinforced CAD/CAM Composite Blocks
10.1922/EJPRD_2207Mangoush09
no access 166 174 £10.00
Comparison of Fit Between Zirconia and Metal Copings Fabricated Conventionally or Using Different CAD/CAM Techniques
10.1922/EJPRD_2108Sambrook07
no access 175 181 £10.00
10-Year Clinical Comparative Study of Ceramic and Composite Veneered Metal Crowns
10.1922/EJPRD_2148Bacher11
no access 182 192 £10.00
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions