European Journal of Prosthodontics and Restorative Dentistry

Twenty-Four-Month Clinical Comparison of Two Bulk-Fill and a Microhybrid Composite Restorations in Class II Cavities

Abstract

Objectives: The aim of this study was to evaluate the clinical performance of two bulk-fill composite resins in Class II cavities for up to twenty-four months. Materials and Methods: In total 75 Class II restorations were made in 25 patients using two nanohybrid bulk-fill resin composites and a microhybrid composite. The restorations were evaluated at baseline and at 6, 12, and 24 months, using U.S. Public Health Service (USPHS) criteria. The restoration groups were compared using the Pearson chi-square test, and the Cochran Q-test was used to compare the changes across different time points within restorative materials (p<0.05). Results: Two patients who did not attend the appointments were excluded from the study, so 23 patients were evaluated with a 92% recall rate; at the end of the two-year follow-up, 66 restorations were evaluated. Three restorations underwent endodontic treatment and were deemed failures. The overall success rate was 96%. There were statistically significant differences between the three restorative resins in terms of color match parameter (p<0.05). No differences were observed between the restorative resins in terms of other criteria (p>0.05). Conclusions: During the two-year follow-up period, the three composite resins showed similar clinical performance except for the color match parameter.
Keywords
Clinical Study
Resin-Based Composite
Bulk-Fill
Class II
USPHS Criteria

Authors

Emine Sirin Karaarslan, Fatma Aytac Bal, Mehmet Buldur, Halenur Altan

Articles from this issue

Title / DOI Access Page Start Page End Purchase
Influence of Platform Switching, Abutment Design and Connection Protocols on the Stability of Peri-Implant Tissues. A Systematic Review
10.1922/EJPRD_2146Soliman14
no access 194 207 £10.00
Cracked Tooth Syndrome: Assessment, Prognosis and Predictable Management Strategies
10.1922/EJPRD_2232Gill09
no access 209 217 £10.00
Effect of Arch Size and Implant Angulations on the Accuracy of Implant Impressions
10.1922/EJPRD_2274MirMohammadRezaei05
no access 218 222 £10.00
Optimal Use of Physical Centric Relation Records for Digital Workflows
10.1922/EJPRD_2263Osnes07
no access 223 229 £10.00
Twenty-Four-Month Clinical Comparison of Two Bulk-Fill and a Microhybrid Composite Restorations in Class II Cavities
10.1922/EJPRD_2189Karaaslan10
no access 231 240 £10.00
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions