European Journal of Prosthodontics and Restorative Dentistry

An In-Vitro Investigation of the Accuracy of Fit of Procera and Empress Crowns

Abstract

The current study aimed to investigate the accuracy of fit and the reproducibility of inner crown profile for two types of high strength ceramics, IPS Empress and Procera. Procera and Empress crowns with four different morphologies were cemented to dies using zinc phosphate dental cement. Vertical and horizontal
sections were made through each of the crown/die preparations and images of the vertical sections were compared for curvature reproduction by alignment using image processing. Measurements were made on horizontal sections to determine cement layer thickness. Alignment of the crowns using image analysis identified quantifiable variations in the inner surface profile compared with the outer surface of the die. The largest differences occurred from the cusp tips to the occlusal adaptation area and differences in surface profile were less pronounced for Procera than Empress crowns. Marginal gap varied independently of ceramic or internal crown shape from 7-529 mm for Procera and 26-548 mm for Empress. IPS Empress has a superior ability to reproduce the inner surface profile of the crown morphologies investigated compared with Procera. The reduced reproduction of surface profile was associated with an increased cement thickness at the occlusal contact area that may inadvertently lead to failure of the crowns functional characteristics.
KEY WORDS: Accuracy of fit, Procera, IPS Empress, Inner crown surface profile, Image analysis

Authors

Garry J.P. Fleming, Marie M. Dobinson†, Gabriel Landini‡, Jonathan J. Harris

Articles from this issue

Title / DOI Access Page Start Page End Purchase
Guest Editorial: The complete denture crisis: a personal view
no access 98 99 £
Comparison of Convergence Angles Achieved in Posterior Teeth Prepared for Full Veneer Crowns
no access 100 104 £
Does the Nature of the Definitive Impression Material Influence the Outcome of (Mandibular) Complete Dentures?
no access 105 108 £
An In-Vitro Investigation of the Accuracy of Fit of Procera and Empress Crowns
no access 109 114 £
Brightness (Value) Sequence for the Vita Lumin Classic™ Shade Guide Reassessed
no access 115 118 £
An In Vitro Investigation of Water Sorption and Solubility of Two Acetal Denture Base Materials
no access 119 122 £
A Quantitative Study of Enamel Acid Etch Patterns on Surfaces Used for Retention of Resin-bonded Fixed Prostheses
no access 123 128 £
The Dental Treatment Needs and Oral Side Effects of Patients Undergoing Outpatient Cancer Chemotherapy
no access 129 134 £
The Use of a Removable Appliance to Relieve Symptoms of Burning Lower Lip in a Dentate Patient
no access 135 138 £
Antibacterial Activities of MDPB and Fluoride in Dentin Bonding Agents
no access 139 142 £
Book Review
no access 143 143 £
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions