European Journal of Prosthodontics and Restorative Dentistry

Evaluation of Clinical Periodontal Parameters of Abutment Teeth Supporting Distal-Extension Base Removable Partial Dentures: A Cross-sectional Study

Abstract

To assess the clinical periodontal status of abutment teeth in regards of different design components of distal-extension removable partial dentures. Subjects (N=100) with acrylic or cobalt-chromium distal-extension removable partial dentures were enrolled and their periodontal parameters plaque and gingival indices [PI, GI], probing depths [PD], clinical attachment loss [CAL] and a mobility index [MI] evaluated. Denture base type, major connector, occlusal rests position, design of direct retainers, retention, stability and denture wearing habits were further evaluated. Acrylic RPDs were associated with higher mean±SE PI [1.70±0.74], GI [1.76±0.55], PD scores [2.47±1.02 mm] and CAL values [4.46±2.11 mm] compared to CO-CR RPDs [p<0.05]. For abutments, the PI [1.6±0.83], GI [1.72±0.57], PD [2.32±1.03] and CAL [4.26±2.08] were higher than their non-abutments counterparts [p<0.05]. CAL scores were found to be significantly higher for mandibular abutments compared to maxillary ones [P=0.002]. The highest PI [1.83±1.10] and GI [2.00±0.00] scores were associated with lingual bars and horse-shoe connectors, respectively. Full palatal coverage and lingual plates were associated with the highest PD [2.80±0.48] and CAL [4.70±0.37] scores. Acrylic RPDs, type of major connector, wrought wire clasps and distal occlusal rests may be considered as risk factors for periodontal disease progression in distal-extension removable partial denture wearers.

Keywords
Clinical Attachment Loss
RPD
Distal Extension
Abutment Tooth
Periodontal
Clinical study

Authors

Ziad N. AL-Dwairi, Dafi S. Taani, Aleh Z. Naseeb, Nadin Al-Haj Husain, Mutlu Özcan, Edward Lynch

Articles from this issue

Title / DOI Access Page Start Page End Purchase
Impact of Finishing and Polishing Procedures on CAD/CAM In Vitro Milled Ceramics Surfaces: A Systematic Review
10.1922/EJPRD_2520Canceill11
no access 321 331 £10.00
Factors that Affect the Shear Bond Strength of Pit and Fissure Sealants to Tooth Structure: A Systematic Review
10.1922/EJPRD_2503Ferreira14
no access 332 345 £10.00
The Effect of Colloidal Silica and Glaze Coatings on the Adhesion of Zirconia with Various Ytrria Concentration
10.1922/EJPRD_2491Villanova12
no access 346 357 £10.00
Titanium Dioxide/Graphene Oxide Composite Coatings for 316 Stainless Steel Dental Implants
10.1922/EJPRD_2511Al-Noaman15
no access 358 372 £10.00
Accuracy of Static Computer Assisted Implant Placement in Posterior Edentulous Areas with Different Levels of ToothSupport by Novice Clinicians
10.1922/EJPRD_2494Abduo10
no access 373 382 £10.00
Effect of Thickness and Translucency on Color Change and Masking Ability of Ceramic Materials used for Laminate Veneers
10.1922/EJPRD_2501Ayata08
no access 383 390 £10.00
Comparative Evaluation of Apically Extruded Debris During Root Canal Preparation Using Three Different File Systems Applied Under 2.5% Sodium Hypochlorite or 2% CHX Irrigation
10.1922/EJPRD_2499Zareana07
no access 391 397 £10.00
Strength of a Zirconia Reinforced Glass-Ceramic After Diamond Bur Adjustment
10.1922/EJPRD_2468MouraPereira09
no access 398 406 £10.00
A Stereophotogrammetry Face Study Between Dentate and Edentulous Adults Rehabilitated with Either a Conventional Complete or an Implant-Supported Fixed Complete Denture
10.1922/EJPRD_2530Pucciarelli09
no access 407 415 £10.00
Comparison of Different Digital Color Measurement Methods on Maxillary Anterior and Canine Teeth: A Clinical Observational Study
10.1922/EJPRD_2541Oberuck08
no access 416 423 £10.00
Evaluation of Clinical Periodontal Parameters of Abutment Teeth Supporting Distal-Extension Base Removable Partial Dentures: A Cross-sectional Study
10.1922/EJPRD_2500AlDwairi09
no access 424 431 £10.00
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions