An Assessment of 1067 Light Curing Units Measured Twice Between 2015 and 2021

Abstract

Introduction: The physical condition of the tip and the irradiance of LCUs used in dental offices in the United States and Canada was assessed twice. Methods: The tip irradiance and physical condition of the tip of 1067 LCUs from 544 dental clinics were assessed twice between 2015 and 2021 using the CheckMARC (BlueLight) radiometer. The irradiance values were compared by paired Student’s t-test (α = 0.05). Results: There was a wide range of irradiance values (200 to 3,777 mW/cm2). At the first assessment, only 26% of the LCUs had no visible damage or debris on the LCU tip. When retested up to 36 months later, 70% of the LCUs had their tip damage or debris issues entirely or partially resolved. 2.6% of the LCUs delivered an irradiance below 500 mW/cm2 on the first and 1.6% on the second assessments. For the 5 brands that had a sufficient sample size, it was concluded that the irradiance increased when the tip damage or presence of tip debris was resolved. Conclusions: Initially, most LCUs (74%) had at least one problem related to damage or debris on the LCU tip. The irradiance increased when the tip damage or debris was resolved.

Keywords
Evaluation
Longitudinal Study
Calibration
Dental Curing Lights
Damage

Authors

Richard B. Price, Jack L. Ferracane, Chris Felix, Franklin Che

Articles from this issue

Title / DOI Access Page Start Page End Purchase
Progressive Tooth Wear Against Resin-Based Restorative Composites
10.1922/EJPRD_2636Bettker10
no access 244 253 £
Does the Incorporation of Graphene Oxide into PMMA Influence its Antimicrobial Activity?
10.1922/EJPRD_2651Ferreira07
no access 254 260 £
Influence of Different Undercut Depths of Clasp Fabricated by Selective Laser Melting on Retentive Force free access 261 269 view
Long-Term Bonding Efficacy of CAD/CAM Hybrid Restorative Materials and Universal Adhesives
10.1922/EJPRD_2455Bashary07
no access 270 276 £
Clinical Performance of Short Fibre-reinforced Glass Ionomer Cement Restorations in Cervical Carious Lesions: 12-Month Randomized Clinical Trial
10.1922/EJPRD_2673AbdElAziz10
no access 277 286 £
Accuracy of Dental Implant Placement using Robotics. A Systematic Review of in vitro Studies
10.1922/EJPRD_2669Ravipati14
no access 287 300 £
Ability of Six Curing Lights to Photocure Four Resin-Based Composites in a MOD-Mold: A Double-Blind Study
10.1922/EJPRD_2661Comisi13
no access 301 313 £
Effect of Surface Treatment on Titanium Surface Free Energy and its Relation to Bacterial Activity: A Systematic Review
10.1922/EJPRD_2609Soares12
no access 314 325 £
Influence of Luminosity on the Precision and Accuracy of Intraoral Scanning: A Comparative in vitro Study
10.1922/EJPRD_2660Viana09
no access 326 334 £
Comparative Evaluation of Microtensile Dentin Bond Strength and Interfacial Micromorphology of Three Universal Adhesives
10.1922/EJPRD_2706Fathy11
no access 335 345 £
An Assessment of 1067 Light Curing Units Measured Twice Between 2015 and 2021
10.1922/EJPRD_2693Price10
no access 346 355 £
Prosthetic Maintenance Assessment for Two Implant- Retained Overdentures Reinforced with PEKK Versus Co-Cr Framework: A Randomized Controlled Clinical Trial
no access 356 364 £
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions