European Journal of Prosthodontics and Restorative Dentistry

Letter to the Editor

Abstract

The authors wish to acknowledge that the information on the Monet website9 has now changed (2024) to reflect that exposures longer than 3 seconds are required for larger restorations and that overlapping exposures should be used. The website now states that for preparation areas that are larger than 5mm in depth and 8mm in diameter, two overlapping spot cures of 3 seconds are recommended (Figure 2). The single 1 and 3x1second exposure times used in the article are not recommended by the manufacturer and should now be considered ‘off-label’ use of the Monet.
Keywords
Letter to the Editor

Authors

Richard Price, John C Comisi, Cristiane Maucoski

Articles from this issue

Title / DOI Access Page Start Page End Purchase
Editorial: A Journal with a Vision into the Evolution of the Dental Profession free access 365 365 view
Letter to the Editor
10.1922/EJPRD_2751PriceLetter03
no access 366 368 £10.00
Effect of Virtual Casts Superimposition Strategies on the Estimation of IOS Accuracy in Complete-Arch Scans
10.1922/EJPRD_2737Grande08
no access 369 376 £10.00
Effect of Repeated Firings on Color Stability of Zirconia Reinforced Lithium Silicate and Lithium Disilicate Ceramics
10.1922/EJPRD_2466Habibkhodaei07
no access 377 383 £10.00
Tensile Bond Strength, Fit Accuracy and Failure Types of Zirconia and Cast Gold Root Copings for Overdentures
10.1922/EJPRD_2685Muehlemann08
no access 384 391 £10.00
Survival and Complication Rates of Polymer-Infiltrated Ceramic-Network Single Tooth Restorations with an Observation Period of up to Three Years
10.1922/EJPRD_2525Polat06
no access 392 397 £10.00
Clinical Survival of Indirect, Posterior Fiber-Reinforced Composite Fixed Dental Prosthesis: Up to 15 Years of Prospective Clinical Follow Up
10.1922/EJPRD_2656Barabanti05
no access 398 402 £10.00
Success and Survival of Composite Resin Restorations for the Management of Localized Anterior Tooth Wear: A Systematic Review and Meta-Analysis
10.1922/EJPRD_2576Aziz12
no access 403 414 £10.00
O-Ring and Bar-Clip: A Comparative Analysis of Retention in Overdenture Prostheses – A Systematic Review
10.1922/EJPRD_2727Araujo08
no access 415 422 £10.00
Effect of Surface Treatments on the Bond Strength of Computer-aided Design and Computer-aided Manufacturing Lithium Disilicate to Restorative Materials: A Systematic Review
10.1922/EJPRD_2777Shoorgashi11
no access 423 433 £10.00
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions