Assessment of Efficacy of Implant Screwdrivers’ During Multiple Tightening/ Untightening Cycles. An in vitro Study

Abstract

Introduction: It is unclear the number of times a screwdriver may be reused without loosening its efficacy or inducing damage to implant screws while keeping appropriate torque values. Objective: Evaluate the effect of the screwdriver and internal threads on the tightening efficacy by assessing the reverse torque value (RTV). Methods: The efficacy was tested with four groups of screws: two titanium groups and two gold-platted (n=5). Each screw was tightened 10 times at 20 Ncm using the screwdriver attached to ISD900 (NSK®). In the first protocol one implant was used for the five screws. In the second protocol for each screw a new implant was used. At each untightening, the RTV was measured and recorded. Results: RTVs for Gold were statistically lower compared to the Titanium. The RTVs differed among the tested screws. In the first protocol, the first serie tightening/untightening differed statistically from the last three series. Conclusion: Titanium screws from Zimmer Biomet achieve better RTV than gold-platted. By increasing the number cycles it is expected to have a decrease in the RTV. The extensive use of screwdrivers and the internal threads of the dental implants might be factors influencing the loss of RTV.

Keywords
Torque
Denture
Dental Implants
Dental Materials
Prosthesis
Biomedical

Authors

Ricardo Batista, André Moreira, Nuno Alves, Maria Helena Figueiral, João Carlos Sampaio-Fernandes

Articles from this issue

Title / DOI Access Page Start Page End Purchase
Clinical Performance of 3D Printed Resin Composite Posterior Fixed Dental Prosthesis: A Permanent Solution?
10.1922/EJPRD_2796Hobbi10
no access 1 10 £10.00
Hybrid Full-Arch Rehabilitation Using Conventional And Zygomatic Implants: A Short-Term Retrospective Analysis
10.1922/EJPRD_2773Grandi13
no access 11 23 £10.00
Assessment of Efficacy of Implant Screwdrivers’ During Multiple Tightening/ Untightening Cycles. An in vitro Study
10.1922/EJPRD_2743Batista09
no access 24 32 £10.00
Does the Learning Curve for Intraoral Scanning Vary Depending on the Device?
10.1922/EJPRD_2766Borges09
no access 33 41 £10.00
Cement Thickness of CAD/ CAM Zirconia Laminate Veneers: Impact of Preparation Design
10.1922/EJPRD_2841Bennani07
no access 42 48 £10.00
Improving the Accuracy of Dental Impressions: A Study of Tray Adjustments and Materials
10.1922/EJPRD_2824Naidu08
no access 49 56 £10.00
Effect of Dentin Pretreatment using Arginine, Polyamidoamine Dendrimer and their Combination on Bond Durability and Micromorphology
10.1922/EJPRD_2829Aboelwafa08
no access 57 64 £10.00
Performance of Fiberglass Posts Versus FiberReinforced Resin Composites in Endodontically Treated Anterior Teeth Without Ferrule: A Systematic Review
10.1922/EJPRD_2802GuzmanReyes18
no access 65 82 £10.00
Influence of the Incorporation of Antimicrobials on the Impact Strength of Acrylic Resins: A Scoping Review
10.1922/EJPRD_2735Ferreira10
no access 83 92 £10.00
Influence of Surface Roughness on the Adhesion of Hydroxyapatite Coatings to Titanium and Titanium Alloy Surfaces: A Systematic Review of in vitro Experimental Studies
10.1922/EJPRD_2776Melo-Soares11
no access 93 103 £10.00
Accuracy of Intra-Oral Scanners for Full Crown Tooth Preparations with Subgingival Margins: A Systematic Review
10.1922/EJPRD_2812Matias09
no access 104 112 £10.00
Description and Durability of the Various Direct Restoration Techniques in Molar-Incisor Hypomineralization: A Systematic Review
10.1922/EJPRD_2760Denis10
no access 113 122 £10.00
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions