European Journal of Prosthodontics and Restorative Dentistry

Accuracy of Intra-Oral Scanners for Full Crown Tooth Preparations with Subgingival Margins: A Systematic Review

Abstract

Introduction: The accuracy of intra-oral scanners (IOS) has not been thoroughly evaluated across all clinical scenarios, particularly in crown preparations with subgingival margins. Objectives: This systematic review aims to assess the accuracy of IOS in tooth preparations with subgingival margins and identify factors influencing their performance in these situations. Methods: A comprehensive literature search was conducted in databases including PubMed, Scopus, Embase, Medline, Google Scholar, and Web of Science for studies published in the last five years. Quality Assessment Tool for In-Vitro Studies (QUIN) was used to evaluate study quality. Results: Out of 605 studies, seven met the inclusion and exclusion criteria. The review found that the trueness of IOS is significantly
compromised in subgingival margins, often failing to achieve clinically acceptable results. Influencing factors included gingival retraction and saliva contamination. Specifically, cord retraction enhanced IOS accuracy, while saliva contamination reduced it. Conclusions: The accuracy of IOS in crown preparations with subgingival margins is severely affected by saliva contamination and visibility issues. Clinically acceptable results are achieved with proper gingival retraction and a dry field. Clinical Relevance: To ensure accurate scanning for tooth preparations with subgingival margins, achieving proper gingival retraction and dryness is crucial.

Keywords
Accuracy
Digital Impression
Trueness
Tooth Preparation
Subgingival Margin
Intraoral Scanner

Authors

MatĂ­as Andrade Villalobos, Vincent Bennani, John M. Aarts, Jithendra Ratnayake

Articles from this issue

Title / DOI Access Page Start Page End Purchase
Clinical Performance of 3D Printed Resin Composite Posterior Fixed Dental Prosthesis: A Permanent Solution?
10.1922/EJPRD_2796Hobbi10
no access 1 10 £10.00
Hybrid Full-Arch Rehabilitation Using Conventional And Zygomatic Implants: A Short-Term Retrospective Analysis
10.1922/EJPRD_2773Grandi13
no access 11 23 £10.00
Assessment of Efficacy of Implant Screwdrivers’ During Multiple Tightening/ Untightening Cycles. An in vitro Study
10.1922/EJPRD_2743Batista09
no access 24 32 £10.00
Does the Learning Curve for Intraoral Scanning Vary Depending on the Device?
10.1922/EJPRD_2766Borges09
no access 33 41 £10.00
Cement Thickness of CAD/ CAM Zirconia Laminate Veneers: Impact of Preparation Design
10.1922/EJPRD_2841Bennani07
no access 42 48 £10.00
Improving the Accuracy of Dental Impressions: A Study of Tray Adjustments and Materials
10.1922/EJPRD_2824Naidu08
no access 49 56 £10.00
Effect of Dentin Pretreatment using Arginine, Polyamidoamine Dendrimer and their Combination on Bond Durability and Micromorphology
10.1922/EJPRD_2829Aboelwafa08
no access 57 64 £10.00
Performance of Fiberglass Posts Versus FiberReinforced Resin Composites in Endodontically Treated Anterior Teeth Without Ferrule: A Systematic Review
10.1922/EJPRD_2802GuzmanReyes18
no access 65 82 £10.00
Influence of the Incorporation of Antimicrobials on the Impact Strength of Acrylic Resins: A Scoping Review
10.1922/EJPRD_2735Ferreira10
no access 83 92 £10.00
Influence of Surface Roughness on the Adhesion of Hydroxyapatite Coatings to Titanium and Titanium Alloy Surfaces: A Systematic Review of in vitro Experimental Studies
10.1922/EJPRD_2776Melo-Soares11
no access 93 103 £10.00
Accuracy of Intra-Oral Scanners for Full Crown Tooth Preparations with Subgingival Margins: A Systematic Review
10.1922/EJPRD_2812Matias09
no access 104 112 £10.00
Description and Durability of the Various Direct Restoration Techniques in Molar-Incisor Hypomineralization: A Systematic Review
10.1922/EJPRD_2760Denis10
no access 113 122 £10.00
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions