European Journal of Prosthodontics and Restorative Dentistry

Cement Thickness of CAD/ CAM Zirconia Laminate Veneers: Impact of Preparation Design

Abstract

Introduction: This study assessed cement thickness of three veneer preparation designs: feather edge, shoulder, and shoulder with wings. Objectives: The aim was to evaluate whether the modified shoulder with wings design produced a similar cement thickness compared to the traditional shoulder and feather edge designs. Methods: The study measured vertical, horizontal, and overall cement thickness of 60 veneer cemented (20 per group) on typodont teeth. Ceramic veneers were fabricated using CAD/CAM with each veneer assessed for fit before cementation. Ten specimens were cut vertically, and 10 were cut horizontally in each group. The cement thickness was measured for each cross-section with scanning electron microscopy. Descriptive data analysis and hypothesis testing were conducted using the nonparametric Kruskal Wallis test (α=.05). Results: In vertical dimension, shoulder with wings design showed the smallest cement thickness. When comparing horizontal and overall cement thickness, the shoulder and shoulder with wings designs were similar. Both shoulder designs produced less overall cement thickness than the feather edge design. Conclusions: Shoulder with wings preparation produced the thinnest cement layer in vertical dimension and a comparable overall cement thickness to the shoulder design. Clinical Relevance: Modified shoulder with wings could enhance veneer longevity by reducing vertical cement thickness.

Keywords
Shoulder
Preparation Design
Veneer Preparation
Feather Edge
Cement Thickness

Authors

Vincent Bennani, John M. Aarts, Arthi Veerasamy

Articles from this issue

Title / DOI Access Page Start Page End Purchase
Clinical Performance of 3D Printed Resin Composite Posterior Fixed Dental Prosthesis: A Permanent Solution?
10.1922/EJPRD_2796Hobbi10
no access 1 10 £10.00
Hybrid Full-Arch Rehabilitation Using Conventional And Zygomatic Implants: A Short-Term Retrospective Analysis
10.1922/EJPRD_2773Grandi13
no access 11 23 £10.00
Assessment of Efficacy of Implant Screwdrivers’ During Multiple Tightening/ Untightening Cycles. An in vitro Study
10.1922/EJPRD_2743Batista09
no access 24 32 £10.00
Does the Learning Curve for Intraoral Scanning Vary Depending on the Device?
10.1922/EJPRD_2766Borges09
no access 33 41 £10.00
Cement Thickness of CAD/ CAM Zirconia Laminate Veneers: Impact of Preparation Design
10.1922/EJPRD_2841Bennani07
no access 42 48 £10.00
Improving the Accuracy of Dental Impressions: A Study of Tray Adjustments and Materials
10.1922/EJPRD_2824Naidu08
no access 49 56 £10.00
Effect of Dentin Pretreatment using Arginine, Polyamidoamine Dendrimer and their Combination on Bond Durability and Micromorphology
10.1922/EJPRD_2829Aboelwafa08
no access 57 64 £10.00
Performance of Fiberglass Posts Versus FiberReinforced Resin Composites in Endodontically Treated Anterior Teeth Without Ferrule: A Systematic Review
10.1922/EJPRD_2802GuzmanReyes18
no access 65 82 £10.00
Influence of the Incorporation of Antimicrobials on the Impact Strength of Acrylic Resins: A Scoping Review
10.1922/EJPRD_2735Ferreira10
no access 83 92 £10.00
Influence of Surface Roughness on the Adhesion of Hydroxyapatite Coatings to Titanium and Titanium Alloy Surfaces: A Systematic Review of in vitro Experimental Studies
10.1922/EJPRD_2776Melo-Soares11
no access 93 103 £10.00
Accuracy of Intra-Oral Scanners for Full Crown Tooth Preparations with Subgingival Margins: A Systematic Review
10.1922/EJPRD_2812Matias09
no access 104 112 £10.00
Description and Durability of the Various Direct Restoration Techniques in Molar-Incisor Hypomineralization: A Systematic Review
10.1922/EJPRD_2760Denis10
no access 113 122 £10.00
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions