European Journal of Prosthodontics and Restorative Dentistry

Clinical Performance of 3D Printed Resin Composite Posterior Fixed Dental Prosthesis: A Permanent Solution?

Abstract

Objectives: This clinical trial aimed to evaluate the clinical outcomes of 3D-printed resin composite posterior fixed dental prosthesis (FDP) restorations. Materials and Methods: Between October 2020 and August 2022, 49 patients (33 females, 16 males, aged 19-60) received 68 3-unit 3D-printed resin composite posterior FDPs (ELS Even Stronger, Saremco, Switzerland). Follow-ups were conducted at baseline (2 weeks) by independent observers using modified FDI criteria, assessing anatomical form, marginal adaptation, surface roughness, color match, fracture, retention, and patient feedback. Fifty FDPs completed a 1-year follow-up, and 18 reached 2 years. Results: The mean observation period was 14.15 months. Failures were categorized as mechanical or biological, with 19 FDPs failing: 14 mechanical (12 cohesive fractures) and 5 biological (3 needing endodontic treatment, 2 periodontal issues). Two FDPs were recemented. Three FDPs showed surface luster loss, color mismatches, and staining. The survival rate based on mechanical failures was 69.5%, dropping to 61.0% when including biological complications. Conclusions: After 2 years, 3D-printed resin composite FDPs demonstrated acceptable performance, with most failures due to fractures in the connector region, suggesting the need for design revisions.

Keywords
Survival
Prosthodontics
Clinical Trial
Dental Materials
Composite 3-Unit Posterior FDPs,
Restorative Materials

Authors

Paniz Hobbi, Tugce M. Ordueri, Funda Öztürk-Bozkurt, Tugba Toz-Akalın, Mehmet M. Ateş, Mutlu Özcan

Articles from this issue

Title / DOI Access Page Start Page End Purchase
Clinical Performance of 3D Printed Resin Composite Posterior Fixed Dental Prosthesis: A Permanent Solution?
10.1922/EJPRD_2796Hobbi10
no access 1 10 £10.00
Hybrid Full-Arch Rehabilitation Using Conventional And Zygomatic Implants: A Short-Term Retrospective Analysis
10.1922/EJPRD_2773Grandi13
no access 11 23 £10.00
Assessment of Efficacy of Implant Screwdrivers’ During Multiple Tightening/ Untightening Cycles. An in vitro Study
10.1922/EJPRD_2743Batista09
no access 24 32 £10.00
Does the Learning Curve for Intraoral Scanning Vary Depending on the Device?
10.1922/EJPRD_2766Borges09
no access 33 41 £10.00
Cement Thickness of CAD/ CAM Zirconia Laminate Veneers: Impact of Preparation Design
10.1922/EJPRD_2841Bennani07
no access 42 48 £10.00
Improving the Accuracy of Dental Impressions: A Study of Tray Adjustments and Materials
10.1922/EJPRD_2824Naidu08
no access 49 56 £10.00
Effect of Dentin Pretreatment using Arginine, Polyamidoamine Dendrimer and their Combination on Bond Durability and Micromorphology
10.1922/EJPRD_2829Aboelwafa08
no access 57 64 £10.00
Performance of Fiberglass Posts Versus FiberReinforced Resin Composites in Endodontically Treated Anterior Teeth Without Ferrule: A Systematic Review
10.1922/EJPRD_2802GuzmanReyes18
no access 65 82 £10.00
Influence of the Incorporation of Antimicrobials on the Impact Strength of Acrylic Resins: A Scoping Review
10.1922/EJPRD_2735Ferreira10
no access 83 92 £10.00
Influence of Surface Roughness on the Adhesion of Hydroxyapatite Coatings to Titanium and Titanium Alloy Surfaces: A Systematic Review of in vitro Experimental Studies
10.1922/EJPRD_2776Melo-Soares11
no access 93 103 £10.00
Accuracy of Intra-Oral Scanners for Full Crown Tooth Preparations with Subgingival Margins: A Systematic Review
10.1922/EJPRD_2812Matias09
no access 104 112 £10.00
Description and Durability of the Various Direct Restoration Techniques in Molar-Incisor Hypomineralization: A Systematic Review
10.1922/EJPRD_2760Denis10
no access 113 122 £10.00
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions