European Journal of Prosthodontics and Restorative Dentistry

Influence of the Incorporation of Antimicrobials on the Impact Strength of Acrylic Resins: A Scoping Review

Abstract

Introduction: The incorporation of antimicrobials into acrylic resins promotes the reduction of pathogenic microorganisms and positive impact on the health of users of prosthetic devices. This incorporation may cause changes in the physicochemical and mechanical properties, such as impact strength. Objective: The objective was to answer the question “Does the incorporation of antimicrobials alter the impact strength of acrylic resins?” Methods: The Preferred Reporting Items for Systematic Reviews and Extension of Meta-Analyses for Scoping Reviews (PRISMA-ScR) Checklist guidelines were used. SCOPUS, PubMed, EMBASE, and Science Direct databases were used with the custom search strategy. Studies were selected in two steps. Risk of bias analysis was performed with the quasi-experimental studies tool by the Joanna Briggs Institute (JBI). Results: As a result, 826 articles were found in the databases, and after removing duplicates and applying the proposed eligibility criteria, 11 studies were selected for the qualitative analysis. After applying the JBI tool, a low risk of bias was deferred to all studies. Due to the heterogeneity of the studies, it was not possible to provide a meta-analysis. Conclusion: The incorporation of antimicrobial agents into acrylic resins can, depending on the antimicrobial and the incorporation technique, affect impact strength.

Keywords
PMMA
Impact Strength
Acrylic Resin
Antimicrobial Agent

Authors

Izabela Ferreira, José A. M. Agnelli, Andrea C. dos Reis

Articles from this issue

Title / DOI Access Page Start Page End Purchase
Clinical Performance of 3D Printed Resin Composite Posterior Fixed Dental Prosthesis: A Permanent Solution?
10.1922/EJPRD_2796Hobbi10
no access 1 10 £10.00
Hybrid Full-Arch Rehabilitation Using Conventional And Zygomatic Implants: A Short-Term Retrospective Analysis
10.1922/EJPRD_2773Grandi13
no access 11 23 £10.00
Assessment of Efficacy of Implant Screwdrivers’ During Multiple Tightening/ Untightening Cycles. An in vitro Study
10.1922/EJPRD_2743Batista09
no access 24 32 £10.00
Does the Learning Curve for Intraoral Scanning Vary Depending on the Device?
10.1922/EJPRD_2766Borges09
no access 33 41 £10.00
Cement Thickness of CAD/ CAM Zirconia Laminate Veneers: Impact of Preparation Design
10.1922/EJPRD_2841Bennani07
no access 42 48 £10.00
Improving the Accuracy of Dental Impressions: A Study of Tray Adjustments and Materials
10.1922/EJPRD_2824Naidu08
no access 49 56 £10.00
Effect of Dentin Pretreatment using Arginine, Polyamidoamine Dendrimer and their Combination on Bond Durability and Micromorphology
10.1922/EJPRD_2829Aboelwafa08
no access 57 64 £10.00
Performance of Fiberglass Posts Versus FiberReinforced Resin Composites in Endodontically Treated Anterior Teeth Without Ferrule: A Systematic Review
10.1922/EJPRD_2802GuzmanReyes18
no access 65 82 £10.00
Influence of the Incorporation of Antimicrobials on the Impact Strength of Acrylic Resins: A Scoping Review
10.1922/EJPRD_2735Ferreira10
no access 83 92 £10.00
Influence of Surface Roughness on the Adhesion of Hydroxyapatite Coatings to Titanium and Titanium Alloy Surfaces: A Systematic Review of in vitro Experimental Studies
10.1922/EJPRD_2776Melo-Soares11
no access 93 103 £10.00
Accuracy of Intra-Oral Scanners for Full Crown Tooth Preparations with Subgingival Margins: A Systematic Review
10.1922/EJPRD_2812Matias09
no access 104 112 £10.00
Description and Durability of the Various Direct Restoration Techniques in Molar-Incisor Hypomineralization: A Systematic Review
10.1922/EJPRD_2760Denis10
no access 113 122 £10.00
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions