European Journal of Prosthodontics and Restorative Dentistry

Surface Microhardness of a Nanofilled Resin Composite: A Comparison of a Tungsten Halogen and a Light-Emitting Diode Light Curing Unit, in vitro

Abstract

Abstract - Surface microhardness numbers (VHN) have been measured and compared for disk specimens (thickness 1.5 mm) of a commercial nanofilled resin composite cured using a range of exposure times with a quartz tungsten halogen (QTH) and light-emitting diode (LED) light-curing unit (LCU), respectively. Each LCU requires different minimum exposure times to optimise VHN with respect to the internal controls but yield bottom surface / top surface VHN ratios > 0.95 with these optimised exposure times. Both LCUs produce comparable VHNs for the top surfaces at short exposure times but the QTH LCU requires increased exposure time for comparable results with the bottom surfaces. Overall, the LCUs are capable of producing comparable VHN numbers and VHN ratios within the parameters investigated.

KEY WORDS: Resin Composite; Nanofilled, Surface Microhardness; Light-Activation; Tungsten Halogen; Light Emitting Diode; Exposure Times

Authors

Mary O’Reilly, Noel J. Ray, Robert J McConnell, Ailish Hannigan

Articles from this issue

Title / DOI Access Page Start Page End Purchase
Surface Microhardness of a Nanofilled Resin Composite: A Comparison of a Tungsten Halogen and a Light-Emitting Diode Light Curing Unit, in vitro
no access 146 152 £10.00
The Extensively Restored Posterior Tooth has a High Incidence of Tooth Fracture
no access 153 158 £10.00
Influence of Condylar Guide Inclination on Condylar Positioning during Clenching
no access 159 164 £10.00
Assessing the efficacy of Denture Cleaners with Quantitative Light-Induced Fluorescence (QLF)
no access 165 170 £10.00
Colour Effects on Extracted Teeth After a Tooth Whitening Regime: Assessment in an Artificial Oral Cavity
no access 171 176 £10.00
Efficacy of Various Disinfecting Agents on the Reduction of Bacteria from the Surface of Silicone and Polyether Impression Materials
no access 177 182 £10.00
Interface Dimensions of CEREC-3 MOD Onlays
no access 183 189 £10.00
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions