Abstract - Light-cured acrylic resin custom tray material is used in commercial dental laboratories but little evidence-based scientiï¬c information on its physical properties is available. Objectives: This study investigates the dimensional stability of light-cured acrylic resin custom tray material and compares its fracture toughness and flexural strength to a chemically-cured acrylic material. Method: For dimensional stability, 20 light-cured specimens were fabricated and measured 3 times at regular time intervals over 48 hours. Mean shrinkage was calculated for each time interval and the mean values were compared to the standard using the Wilcoxon Rank Sum test. A p-value of <0.05 was considered signiï¬cant. For fracture toughness, 2 groups of 20 light-cured and chemically-cured acrylic materials with a single-edge notch were subjected to a compressive load using the 3-point bending technique. For flexural strength, 1 group (n=20) of each material was subjected to a compressive load using 3-point bending. The highest load before failure was used to calculate the fracture toughness and flexural strength. Differences in fracture toughness and flexural strength values between the 2 groups were compared using ANOVA testing. A p-value of <0.05 was considered signiï¬cant. The chemically-cured group was accepted as the control group. Results: Compared to the standard, shrinkage was signiï¬cant for all time intervals (p<0.05). The difference in shrinkage among time intervals was not signiï¬cant (p>0.05). The fracture toughness and flexural strength were signiï¬cantly higher for the light-cured material. Conclusions: Trays made from light-cured acrylic resin can be used immediately following polymerization. The light-cured material is more resistant to bending and crack propagation than the chemically-cured type.
KEY WORDS: Custom tray; polymethyl methacrylate resin; chemically-cured; light-cured; dimensional stability; fracture toughness; flexural strength.
S. B Khan, G. Geerts