European Journal of Prosthodontics and Restorative Dentistry

Effect of Artificial Saliva and pH on Shear Bond Strength of Resin Cements to Zirconia-Based Ceramic

Abstract

Abstract - The aim of the present study was to evaluate the effect of media with different pH on shear and strength of resin cements to zirconia-based ceramics. Sixty rectangularly shaped specimens made of a zirconia based ceramic (Cercon, Dentsply) were prepared, air-blasted with 110 µm aluminum oxide particles (Al2O3) and randomly assigned into three groups (n=30). A universal resin composite (Filtek Z250, 3M/ESPE) was bonded to each specimen using one of the following three cements: Calibra (Dentsply), Panavia F2 (kurary) and Unicem (3M/ESPE). Specimens were thermal cycled and stored in one of the following three media for two weeks: water at pH=7, saliva at pH=7 and saliva at pH= 3.5. The mean shear bond strength of each group was analyzed using the Kruskal-Wallis test (a=0.05). The modes of failure were recorded using a streomicroscope. All specimens in the Calibra groups showed premature debonding. No significant difference was found between the two other cements or different media. The failure modes in the two latter cements were predominantly adhesive. Despite the adverse effect of acidic media on the properties of restorative materials, the media did not significantly influence the bond strength of MDP-containing resin cement and a self-adhesive cement to a zirconia- based ceramic.

KEYWORDS: zirconia, shear bond strength, resin cement, artificial saliva, pH

Authors

F. Geramipanah, M. Majidpour, L. Sadighpour, M.J. Kharazi Fard

Articles from this issue

Title / DOI Access Page Start Page End Purchase
A Simple Method to Fabricate Stabilized Record Bases: A Modified Approach Using Casting Wax for the Borders
10.1922/EJPRD_1096Morris03
no access 2 4 £10.00
Effect of Artificial Saliva and pH on Shear Bond Strength of Resin Cements to Zirconia-Based Ceramic
10.1922/EJPRD_1065Sadighpour04
no access 5 8 £10.00
Digital Data Management for CAD/CAM Technology. An Update of Current Systems.
10.1922/EJPRD_1014Andreiotelli07
no access 9 15 £10.00
Unilateral Bounded Saddles: A Clinical Case Report on the use of a Two Part Sectional Removable Partial Denture
10.1922/EJPRD_1199Tang08
no access 16 23 £10.00
A Preliminary Evaluation into the Performance of Posterior Resin Bonded Cast Metal Restorations (Adhesive Onlays)
10.1922/EJPRD_1067Marchan05
no access 24 28 £10.00
A Study to Evaluate the Prevalence of Golden Proportion and RED Proportion in Aesthetically Pleasing Smiles
10.1922/EJPRD_1087Meshramkar05
no access 29 33 £10.00
The Effect of Laser Irradiation on Retention of Full Cast Crowns
10.1922/EJPRD_1047-AlOmari06
no access 34 39 £10.00
Provision of an Appliance to Correct Mandibular Deviation Secondary to Temporomandibular Joint Replacement
10.1922/EJPRD_1175Durey04
no access 40 43 £10.00
Evaluation and Comparison of the Internal Fit and Marginal Accuracy of Base Metal (Nickelchromium) and Zirconia Copings Before and after Ceramic Veneering: A Sem Study
10.1922/EJPRD_1152Regish05
no access 44 48 £10.00
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions