Clinical efficiency of one-piece screw-type implants with telescopic were attachments evaluated in this study. Twenty-four patients received a mandibular implant-supported overdenture and maxillary complete denture. Ninety-six one-piece implants were inserted in the inter-foraminal area. Implants were immediately loaded with an implant-retained overdenture and telescopic attachments which had frictional retention elements. There was 0.25±0.24 mm, 0.32±0.25 mm, 0.43±0.30 mm, 0.61±0.30 mm and of bone resorption after 3, 6, 12 and 24 months, respectively. The need to activate the frictional retention was the most common complication. Treatment outcomes for prefabricated telescopic retained overdentures on one-piece implants are similar to that obtained in cases of delayed loading.

Keywords
Osseointegration
Telescopic
Overdenture
One-Piece Implant

Authors

Dr Touraj Nejatian, Dr Shahram Namjoy Nik

Articles from this issue

Title / DOI Access Page Start Page End Purchase
Letter to the Editor - Radiation Injuries: Reemphasizing the Usage of Radiation Protection Prosthesis
10.1922/EJPRD_01650Kohli01
no access 170 170 £10.00
Titanium Corrosion: Implications For Dental Implants
10.1922/EJPRD_1531Shah10
no access 171 180 £10.00
Effect of Implant Diameter And Alloy on Peri-Implant Strain: An In Vitro Quantitative Strain Analysis
10.1922/EJPRD_1558Goonawardhana05
no access 181 185 £10.00
Does Ferrule Effect Affect Implant-Abutment Stability?
10.1922/EJPRD_01607Mohajerfar06
no access 186 191 £10.00
Acrylic Reinforcement with Off the Shelf Perforated Metal Plates
10.1922/EJPRD_01575Abdulhameed05
no access 192 196 £10.00
Qualitative Beam Profiling of Light Curing Units for Resin Based Composites
10.1922/EJPRD_1513Haenel06
no access 197 202 £10.00
The Effect of Irradiation Distance on Light Transmittance and Vickers Hardness Ratio of Two Bulkfill Resin-based Composites
10.1922/EJPRD_1576Almuallem12
no access 203 214 £10.00
One-Piece Implant-Retained Mandibular Overdentures By Pre-Fabricated Titanium Telescopic Attachments and Frictional Varnish: A Two Year Prospective Study
10.1922/EJPRD_01587Nik07
no access 215 221 £10.00
Retrospective Study of the Survival and Patient Satisfaction with Composite Dahl Restorations in the Management of Localised Anterior Tooth Wear
10.1922/EJPRD_01567Aljawad08
no access 222 229 £10.00
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions