European Journal of Prosthodontics and Restorative Dentistry

Letter to the Editor - Radiation Injuries: Reemphasizing the Usage of Radiation Protection Prosthesis

Abstract

ABSTRACT
The margins of copings for crowns and retainers of fixed partial dentures affect the progress of microleakage and dental caries. Failures occur due to altered fit which is also influenced by the method of fabrication. An in-vitro study was conducted to determine among the cast base metal, copy milled zirconia, computer aided designing computer aided machining/manufacturing zirconia and direct metal laser sintered copings which showed best marginal accuracy and internal fit. Forty extracted maxillary premolars were mounted on an acrylic model and reduced occlusally using a milling machine up to a final tooth height of 4 mm from the cementoenamel junction. Axial reduction was accomplished on a surveyor and a chamfer finish line was given. The impressions and dies were made for fabrication of copings which were luted on the prepared teeth under standardized loading, embedded in self-cure acrylic resin, sectioned and observed using scanning electron microscope for internal gap and marginal accuracy. The copings fabricated using direct metal laser sintering technique exhibited best marginal accuracy and
internal fit. Comparison of mean between the four groups by ANOVA and post-hoc Tukey HSD tests showed a statistically significant difference between all the groups (p<0.05). It was concluded that the copings fabricated using direct metal laser sintering technique exhibited best marginal accuracy and internal fit. Additive digital technologies such as direct metal laser sintering could be cost-effective for the clinician, minimize failures related to fit and increase longevity of teeth and prostheses.

Keywords
Casting
Direct Metal Laser Sintering
Internal Fit
Marginal Accuracy
Scanning Electron Microscope

Authors

Dr SHEKHAR BHATIA, Dr SHIVANI KOHLI

Articles from this issue

Title / DOI Access Page Start Page End Purchase
Letter to the Editor - Radiation Injuries: Reemphasizing the Usage of Radiation Protection Prosthesis
10.1922/EJPRD_01650Kohli01
no access 170 170 £10.00
Titanium Corrosion: Implications For Dental Implants
10.1922/EJPRD_1531Shah10
no access 171 180 £10.00
Effect of Implant Diameter And Alloy on Peri-Implant Strain: An In Vitro Quantitative Strain Analysis
10.1922/EJPRD_1558Goonawardhana05
no access 181 185 £10.00
Does Ferrule Effect Affect Implant-Abutment Stability?
10.1922/EJPRD_01607Mohajerfar06
no access 186 191 £10.00
Acrylic Reinforcement with Off the Shelf Perforated Metal Plates
10.1922/EJPRD_01575Abdulhameed05
no access 192 196 £10.00
Qualitative Beam Profiling of Light Curing Units for Resin Based Composites
10.1922/EJPRD_1513Haenel06
no access 197 202 £10.00
The Effect of Irradiation Distance on Light Transmittance and Vickers Hardness Ratio of Two Bulkfill Resin-based Composites
10.1922/EJPRD_1576Almuallem12
no access 203 214 £10.00
One-Piece Implant-Retained Mandibular Overdentures By Pre-Fabricated Titanium Telescopic Attachments and Frictional Varnish: A Two Year Prospective Study
10.1922/EJPRD_01587Nik07
no access 215 221 £10.00
Retrospective Study of the Survival and Patient Satisfaction with Composite Dahl Restorations in the Management of Localised Anterior Tooth Wear
10.1922/EJPRD_01567Aljawad08
no access 222 229 £10.00
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions