European Journal of Prosthodontics and Restorative Dentistry

Mini Dental Implants in the Management of The Atrophic Maxilla and Mandible: A New Implant Design and Preliminary Results

Abstract

The aim of this study was to compare the clinical accuracy of digital and conventional
dental implant impressions. Two types of implant impressions were made for each case,
namely a conventional open-tray impression and a digital implant impression (DII) using
a Trios IOS. Master casts were scanned using a D800 laboratory scanner and STL files
were retrieved from conventional and digital workflows to be exported for comparison.
The distance between center points, angulation, rotation, vertical shift, and surface mismatch
of the scan bodies were evaluated and compared between conventional and digital
impression techniques. Comparing digital and conventional impression techniques
the following factors showed statistically significant differences: distance (73.7±75 μm),
angulation (0.42±0.3º), and surface mismatch of scan bodies. The difference in conventional
and digital impression techniques as regards to angulation and distance between
the implants were associated with distance, angle, and vertical shift differences in scan.
The mismatch of the scanned surface of scan bodies was twice higher for the intraoral
scanner group. Clinicians should therefore control the implant suprastructures clinically
and also using casts (e.g. printed casts) when a digital scan is planned.
Keywords
Dental Implants
Prosthodontics
Digital Impression
Intraoral Scanner
Conventional Impressions

Authors

Prof. Craig William Barclay, Dr. Sarra Jawad, Dr. Emma Foster

Articles from this issue

Title / DOI Access Page Start Page End Purchase
The Effects of Different Spectrophotometric Modes on Colour Measurement of Resin Composite and Porcelain Materials
10.1922/EJPRD_01767Alghazali11
no access 163 173 £10.00
Shade Stability of Polymer Infiltrated and Resin Nano Ceramic Crowns after Dynamic Chewing Simulation
10.1922/EJPRD_01807Schurmann10
no access 174 183 £10.00
Accidental Ingestion of an Implant Screwdriver: A Case Report and Literature Review
10.1922/EJPRD_01800ElWazani06
no access 184 189 £10.00
Mini Dental Implants in the Management of The Atrophic Maxilla and Mandible: A New Implant Design and Preliminary Results
10.1922/EJPRD_01830Barclay07
no access 190 196 £10.00
Prevalence and Factors Associated with the Use of Denture Adhesives by Older Complete Denture Wearers
10.1922/EJPRD_01808Kossioni05
no access 197 201 £10.00
Clinical Evaluation of All Ceramic Zirconia Framework Resin Bonded Bridges
10.1922/EJPRD_01810Shahdad09
no access 203 211 £10.00
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions