European Journal of Prosthodontics and Restorative Dentistry

Accuracy of IOS in Full-Arch Dentate Patients Compared to CBCT Cast-Scanning. An In-Vivo Study

Abstract

Twenty fully-dentate patients were enrolled in the study.Full-arch maxillary and mandibular PVS impressions were acquired using stock metal trays and the dual mix technique. A full-arch maxillary and mandibular intraoral scanner (IOS) was also obtained using the Trios IOS. The impressions were cast and subsequently scanned using a Planmeca Promax cone beam computed tomography (CBCT) scanner. The casts were also scanned in a Desktop Scanner for reference(7series Dental Wings). DICOM files from the CBCT device were converted into stl files. The.stl files from the CBCT and IOS devices were compared for accuracy against the reference files from the Desktop Scanner using a 3D surface measurement software. Statistical analysis was carried out using SPSS software. Trios had a
smaller error (median = 39μm) than CBCT (median = 62μm),a statistically significant difference between the 2 modalities (z=-4.6, p<0.005).Concerning the IOS, the anterior teeth presented with a smaller error (42±16μm) as opposed to the posterior teeth (47±16μm), a significant difference (t(39)=-2.4, p=0,019). There were no significant differences in IOS mean accuracy between maxilla and mandible or between left and right quadrants. Fullarch digitization using the Trios IOS is significantly more accurate compared to CBCT scanning of the relevant plaster models. Anterior teeth Trios IOS is statistically more accurate compared to posterior teeth IOS.

Keywords
Intraoral Scanning
CBCT Scanning
Full-Arch Accuracy

Authors

Dr. George Michelinakis, Dr. Dimitrios Apostolakis, Emmanouil Pavlakis, Georgios Kourakis, Prof. George Papavasiliou

Articles from this issue

Title / DOI Access Page Start Page End Purchase
Evaluation of Smear Layer Removal Using Different Irrigation Methods In Root Canals
10.1922/EJPRD_01817Husain06
no access 97 102 £10.00
Longevity of Bond Strength of an Indirect Composite Resin to Dentin Using Conventional or Self-Adhesive Resin Cementation: Influence of Dentin Pretreatment with TiF4
10.1922/EJPRD_01907Viana10
no access 103 112 £10.00
PEEK High Performance Polymers: A Review of Properties and Clinical Applications in Prosthodontics and Restorative Dentistry
10.1922/EJPRD_01892Zoidis09
no access 113 121 £10.00
Accuracy of IOS in Full-Arch Dentate Patients Compared to CBCT Cast-Scanning. An In-Vivo Study
10.1922/EJPRD_01906Michelinakis09
no access 122 130 £10.00
Clinical Evaluation of Three Types of CAD/CAM Inlay/ Onlay Materials After 1-Year Clinical Follow Up
no access 131 140 £10.00
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions