European Journal of Prosthodontics and Restorative Dentistry

Digital Image Correlation and Finite Element Analysis of Bone Strain Generated by Implant-Retained Cantilever Fixed Prosthesis

Abstract

Purpose: The present study evaluated the displacement and strain generated in an implant-supported fixed prosthesis under axial and non-axial loads using two methods. Materials and Methods: Three implants were inserted in a resin block. The Digital Image Correlation (DIC) was used to measure displacement and strain generated on the surface of the resin blocks for the different load applications (500N, 1 image/second). A 3-dimensional
model was constructed and a load of 500 N was applied at an axial point and a non-axial point through finite element analysis (FEA). Results: Both methods gave similar trends for the strains, and both gave slightly higher strains with non-axial loading. FEA predicted higher strain magnitude (±11%) in comparison with DIC, but with the same mechanical behavior. According to ANOVA, the loading influenced the strain concentration. Higher strain was
generated for non-axial loading around the implant nearest to the loading. Conclusions: For implant-retained cantilever fixed prosthesis, the same load applied in the lever arm induces higher strain in the cervical area of the last implant, which suggests more damaging potential than a load applied at the center of the prosthesis.

Keywords
Dental Implant
Finite Element Analysis
Biomechanical Complications
Computerized Models

Authors

João Paulo M. Tribst, Amanda M. O. Dal Piva, Marco Antonio Bottino, Renato S. Nishioka, Alexandre L. S. Borges, Mutlu Özcan

Articles from this issue

Title / DOI Access Page Start Page End Purchase
Bisphenol A in Dentistry
10.1922/EJPRD_01950Kechagias07
no access 3 9 £10.00
Digital Image Correlation and Finite Element Analysis of Bone Strain Generated by Implant-Retained Cantilever Fixed Prosthesis
10.1922/EJPRD_1941Tribst08
no access 10 17 £10.00
Do Type and Shape of Scan Bodies Affect Accuracy and Time of Digital Implant Impressions?
10.1922/EJPRD_1962Moslemion10
no access 18 27 £10.00
Two-body Wear and Hardness of New Generation Artificial Resin Teeth
10.1922/EJPRD_1958kayacioglu08
no access 28 35 £10.00
Clinical Evaluation of Chairside-Fabricated Partial Crowns Made of Zirconia Reinforced Lithium Silicate Ceramic - 2-Year-Results
10.1922/EJPRD_2001Rinke07
no access 36 42 £10.00
Factors Affecting DecisionMaking For Congenitally Missing Permanent Maxillary Lateral Incisors: A Retrospective Study
10.1922/EJPRD_1959Kafantaris10
no access 43 52 £10.00
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions