Clinical Evaluation of Chairside-Fabricated Partial Crowns Made of Zirconia Reinforced Lithium Silicate Ceramic - 2-Year-Results

Abstract

Introduction: In a prospective study, the clinical performance of chairside-fabricated partial-crowns made of zirconia-reinforced lithiumsilicate (ZLS)-ceramic was evaluated after 2 years. Materials and methods: 45 patients (28 female/17 male) underwent restoration with 61 chairside-fabricated ZLS partial-crowns on vital premolars and molars. In variation from the manufacturer’s recommendations (minimum material thickness (MMT)=1.0 mm), partial-crowns with reduced material thicknesses were fabricated: group 1, MMT=0.5-0.74 mm (n=31); group 2, MMT=0.75-1.0 mm (n=30). The restorations were luted with either a self-adhesive cement (SAC) or the total-etch technique using a dual-curing composite cement (DC). The MMT and cementation technique (SAC vs. DC) were evaluated as possible covariates of the time-dependent survival (SVR) and success rate (SCR) using univariate log-rank-tests. Results: Forty-four patients with 59 restorations participated in the 2-year follow-up examinations. In group 1 (n=31), there were 2 losses due to ceramic fracture (SVR: 94.0% (95% confidence interval (CI): 0.85-1)). In
group 2, no losses were documented (SVR: 100%). In 2 restorations cemented with SAC, recementation was necessary (overall SCR: 93% (CI: 0.87-1)). Conclusion: To avoid early material-related fractures, observing the recommended minimum thickness of 1.0 mm is essential. However, further validation of these results in studies with longer observational periods is required.

Keywords
Clinical Study
Survival Rate
High-Strength Glass-Ceramics
Partial Crown
Success Rate

Authors

Dr. Sven Rinke, Alexandra Brandt, Dr. Tim Hausdoerfer, Dr. Andreas Leha, Prof. Dirk Ziebolz

Articles from this issue

Title / DOI Access Page Start Page End Purchase
Bisphenol A in Dentistry
10.1922/EJPRD_01950Kechagias07
no access 3 9 £10.00
Digital Image Correlation and Finite Element Analysis of Bone Strain Generated by Implant-Retained Cantilever Fixed Prosthesis
10.1922/EJPRD_1941Tribst08
no access 10 17 £10.00
Do Type and Shape of Scan Bodies Affect Accuracy and Time of Digital Implant Impressions?
10.1922/EJPRD_1962Moslemion10
no access 18 27 £10.00
Two-body Wear and Hardness of New Generation Artificial Resin Teeth
10.1922/EJPRD_1958kayacioglu08
no access 28 35 £10.00
Clinical Evaluation of Chairside-Fabricated Partial Crowns Made of Zirconia Reinforced Lithium Silicate Ceramic - 2-Year-Results
10.1922/EJPRD_2001Rinke07
no access 36 42 £10.00
Factors Affecting DecisionMaking For Congenitally Missing Permanent Maxillary Lateral Incisors: A Retrospective Study
10.1922/EJPRD_1959Kafantaris10
no access 43 52 £10.00
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions