SCImago Journal & Country Rank
Clarivate Analytics
Embase
Embase


European Journal of Prosthodontics and Restorative Dentistry

Influence of Short Fiber Reinforced Composites on Fracture Resistance of Single-Structure Restorations

Influence of Short Fiber Reinforced Composites on Fracture Resistance of Single-Structure Restorations

Abstract

Objective: The aim was to determine the load-bearing capacity of anterior crowns prepared using two types of single-structure short fibre-reinforced composites (SFRCs). Furthermore, fracture toughness (FT), flexural strength (FS) and flexural modulus (FM) of tested composites were measured. Methods: Seven groups of composite crowns were designed for an upper central incisor (n=8/group). Two groups were CAD/CAM fabricated made of Cerasmart 270 and experimental single-structure SFRC blocks. Two groups were 3D-printed made of GC Temp PRINT and Pro3dure GR-17 composites. Two groups were made of conventional light-cured composites (Essentia and Gradia Plus). The last group was a single-structure SFRC made of commercial flowable SFRC (everX
Flow). Crown restorations were loaded until fracture. Failure-modes were then visually examined. FT, FS and FM were determined for each tested composite (n=8). The data were analysed using analysis of variance (p=0.05) followed by Tukey’s post-hoc test. Results: ANOVA revealed that crowns made of experimental SFRC blocks had significantly higher load-bearing capacities (1650 ±230 N) (p<0.05) among all the groups tested. Experimental SFRC blocks exhibited the highest FT (2.9 MPa m1/2) and FS (245.8 MPa) values (p<0.05) among tested composites. Conclusion: CAD/CAM fabricated restorations
made of experimental SFRC blocks demonstrated encouraging performance related to their fracture-behaviour.

Keywords
3D-Printing
Fracture Behavior
Single-Structure Restoration
Anterior Crown
Fiber Composite

Authors

Enas Mangoush, Sufyan Garoushi, Pekka K. Vallittu, lippo lassila

Articles from this issue

Title / DOI Access Page Start Page End View
Effect of Implant Position and Attachment Type on the Biomechanical Behavior of Mandibular Single Implant Prostheses
10.1922/EJPRD_2019Grobecker-Karl09
full access 152 160 view
Bond Strength Durability of Adhesive Cements to Translucent Zirconia: Effect of Surface Conditioning
10.1922/EJPRD_2036Sakrana11
full access 161 171 view
Comparison of the Clinical Accuracy of Digital and Conventional Dental Implant Impressions full access 173 181 view
Effect of Potassium Nitrate and Boric Acid on the Bond Strength of Veneering Ceramics to Zirconia
10.1922/EJPRD_Sasany203007
full access 182 188 view
Influence of Short Fiber Reinforced Composites on Fracture Resistance of Single-Structure Restorations
10.1922/EJPRD_2075Mangoush10
full access 189 198 view
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions